Supports selection of bridge voltage
Supports selection of bridge connection method
Each channel supports disconnection detection
Can set standard range, extended range two modes
Protocol | X-bus |
Data Transfer Rates | 6Mb/s |
Connection Method | Reed Contact |
Process data volume: Downlink | 4 Bytes |
Process data volume: Upstream | 12 Bytes |
Power Supply | 5 VDC |
Weight | 120g |
Module Size | 106×73×25.7 mm |
Protect. Class | IP20 |
Operating Temperature | -10℃~+60℃ |
Storage Temperature | -20℃~+75℃ |
Relative Humidity | 95%, no condensation |
Disconnection detection | Support |
Overflow function | Support |
Input Filtering | Configurable |
Channel indicator light | Green LED |
Number of channel | 2 |
Type of sensor | Full-bridge 4-wire/6-wire sensor, half-bridge 3-wire/5-wire sensor |
Connection Method | Full bridge 4-wire system/6-wire system, half bridge 3-wire system/5-wire system. |
Supply Bridge Voltage | 2V /2.5V /3V /3.5V /4V /4.5V /5V |
Conversion speed | 5ms |
Output speed | 1ms |
Input range | Full bridge: ±32mV/V Half bridge: ±16mV/V |
Range Mode | Standard range mode, extended range mode |
Accuracy Requirements | 0.4‰ |
Channel Disabled | Support |
Channel Independent | Support |
Zero point compensation | Half-bridge zero point compensation (16-bit compensation) |