XB6S-1616B

16-channel digital input and output module, Input NPN/PNP compatible, input filter default 3ms, output PNP type

Input compatible with NPN/PNP type input, convenient for flexible use

Input supports type1, type3, the input voltage can go up to 11V, adaptable to more types of sensors

Output field measurement supports surge protection, saving the cost of external surge protectors

Terminals distinguish between positive and negative poles of power supply to prevent misconnection or reverse connection

Add

Interface Parameters

ProtocolX-bus
Data Transfer MediumX-bus Backplane Bus
Bus InterfaceReed Contact
Data Transfer Rates6Mb/s
Electrical IsolationYES

Technical Parameters

Power Supply5VDC(4.5V~5.5V)
Current Consumption100mA
Weight110g
Module Size106.4*25.7*72.3mm
Protect. ClassIP20
Operating Temperature-20℃~+60℃
Storage Temperature-40℃~+80℃
Relative Humidity95 %, no condensation
Module Abnormality Self-RecoverySupport
diagnosisSupport
AlarmSupport
Firmware UpgradeSupport

Digital Input

Nominal Voltage24VDC(20.4V~28.8V)
Number of Inputs16
Transistor PolarityNPN&PNP
Input Current5mA(24VDC)
Electrical Isolation500VAC
IndicatorGreen LED
"0" Signal Voltage-3V~+5V/below 0.9mA(PNP)
11V~30V/above 2.1mA(NPN)
“1” Signal Voltage11V~30V/above 2.1mA(PNP)
-3V~+5V/below 0.9mA(NPN)
Input FilterDefault is 3ms, adjustable range is 0~20 ms
Isolation MethodOptocoupler Isolation
Reaction Time<50us
Input Impedance5.4KΩ
Power consumption0.5W

Digital Output

Nominal Voltage24VDC(20.4V~28.8V)
Number of Outputs16
Transistor PolarityPNP
Load TypeResistive load, Inductive load, Lamp load
Max. Output CurrentMax:0.5A
Port ProtectionReverse Protection (Automatic Recovery Mechanism), On-site Surge Protection
Electrical Isolation500VAC
IndicatorGreen LED
Output Voltage Drop<1V
Leakage Current<10uA
Reaction Time<150us
Isolation MethodOptocoupler Isolation
Power consumption0.5W